Automatic Entrance Systems

We offer a wide range of automatic entrance systems. These include entrance products such as sliding, swinging, revolving and bi-folding doors and low energy closers/operators to comply with the Disability Discrimination Act 1995.

Our entrance systems for example are suitable for use in schools, hospitals, residential homes, offices and retail outlets.

We are able to incorporate access technology into the entrance/exit device such as intercom, emergency, security and fire alarm systems.

Sliding Doors

  • Manufactured to comply with BS7036, Disability Discrimination Act 1995 and the European directive EMC 89/336/EEC
  • Commercial grade aluminium door/composite framework
  • Safety signage and manifestation stripes/circles
  • Single or Double Glazed (Safety glass)
  • Low aluminium threshold
  • Safety sensors/pocket where required to satisfy regulations
  • Commissioned by experienced qualified engineers
  • Colour to specification (Inclusive of header unit)
  • Small and compact header section (Size of header section means it can be installed in most locations)

Below Are Some Example Styles – More available on request
Note – Some styles may not be suited to location

 

Internal shuffle glazed for added security

Internal safety sensors to prevent slide door colliding with traffic

(Above) Style 1 – Single slide door with low ramp threshold activated by external/internal movement/proximity sensors.

(Above) Style 3 – Single slide door with low ramp threshold activated by external/internal movement/proximity sensors. Safety pocket – Internal

(Above) Single slide door with low ramp threshold activated by external/internal movement/proximity sensors. Internal safety sensors to slide area.


Swing Doors (Low Energy Door Operators)

Manufactured to comply with BS7036, Disability Discrimination Act 1995 and the European directive EMC 89/336/EEC

Full range of low energy operators to suit most applications

Functions of Operators:

  • Automatic
  • Door stand open
  • One/two way traffic
  • Night lock
  • Push and go – Manual opening by hand and closing by spring
  • Synchronisation of two operators – Two doors operating simultaneously
  • Safety sensors – Full safety optional extra
  • Push button activation
  • Adjustable time delay
  • Adjustable – slow opening/closing speed

Operator Advantages:

  • Low-Energy
  • Automatic/manual
  • Requires no structural changes
  • Easy installation

 

Low Energy Unit – Fitted to existing door

IPush Pad Entry located at 1mtre from ground level

(Above) Interval view – Automated door via low energy closer

 

 

Internal door fitted with Intercom, Maglock and digital access coded pad
(Linked to fire alarm system)

Wireless radio controlled – Reduces wiring and simplifies fitting process

Key Switch – Auto, open, close, off, exit only and entry only

(Above) External powder coated commercial grade aluminium composite frame with out swing door with integral low threshold ramp. Door operated by 1no. low energy closer. Above fanlight manufactured to suit existing archway. Door glazed in 4mm clear toughened low ‘E’, 16mm cavity and 4mm clear toughened.

 

 

Barrier Rail – Attached 1no. press pad for external application (Entry device)

(Above) External powder coated commercial grade aluminium composite frame with out swing door and integral low threshold ramp with barrier rail. Door operated by 1no. low energy closer. Door glazed in 6mm clear toughened low ‘E’, 12mm cavity and 6mm clear toughened.

(Above) The supply and fitting of 1no. low energy door closer and mag-lock entrance/exit device to existing master/slave powder coated aluminium door by AllGlass Systems Ltd. door engineers.

(Above) 1no. aluminium hexagonal composite with double door powered by 2no. low energy automated door closers. Full top scan safety sensors and EZ+ microwave sensor for early detection and safe passage of door users.

AGS 2004 Header Unit
AGS 3 Position Key Switch (Can be Wall or Frame Mounted)
Articulated Arm (Open Out)
2 Channel Receiver


Closed Position


Part Open



Fully Open

 

AGS 2009 Header Unit
Slide Arm (Open In)
2 Channel Receiver
Fuse Spur (By Others)


Example 1


Example 2


Magnetic Lock – Secure Access


Figure 1 – Front (Frame Mounted)


Figure 2 – Rear (Frame Mounted)



Figure 3 – Door Attachment

 

Mag-Lock

  • Fail Safe
  • Fail Secure (Battery back Up)

Operated by:

  • Emergency Door Release – Figure 4
  • Press to Open 4” Push Pad (Hard Wired/Radio Controlled) – Figure 5
  • Stainless Steel Digital Key Code Pad – Figure 6
  • Infrared Touch-less Switch – Figure 7
  • Handset (Visual/Audio) with Push Button Release
  • Remote Control
  • Integrated with Fire Alarm System (Interfaced by Qualified Systems Technician)

Figure 4 – Emergency Door Release


Figure 5 – Press To Open 4” Push Pad (Transmitter)



Figure 6 – Stainless Steel Digital Key Code Entry System


Figure 7 – Infrared Touch-less Switch



Revolving Doors

  • Manufactured to comply with BS7036, Disability Discrimination Act 1995 and the European directive EMC 89/336/EEC
  • Typical installation sites – Hospitals, Hotels, Supermarkets, Department Stores, Airports and Office Buildings
  • Automatic operation – Activated by motion detectors
  • Safety features/sensors – Emergency stop if door encounters an object, reduced speed and a focused on door system that detects objects within a certain distance.
  • Commissioned and installed by experienced qualified engineers
  • Colour to specification (Inclusive of header unit)
  • Directional control – Security (with optional card access)
  • Manufactured to satisfy the needs of the location/application
  • Safety glass as standard

Bi-folding Doors

  • Manufactured to comply with BS7036, Disability Discrimination Act 1995 and the European directive EMC 89/336/EEC
  • Suited to locations where space is at a premium.
  • Concertina style
  • Designed for use in corridors, hallways, small vestibules or disabled entrances
  • Accommodates two way traffic
  • Commissioned and installed by experienced qualified engineers
  • Colour to specification (Inclusive of header unit)
  • Manufactured to satisfy the needs of the location/application
  • Safety glass as standard

Conversion of Existing Internal Door Set to Automated

(Above) 2no. low energy automated door operators with slide arm and top scan safety door sensors. Both operators initiated by 2no. radio controlled (transmitter/receiver) 4" push pads to either side of door. Push and go facility enabled on door set. Full signage.

(Above) 2no. low energy automated door operators with slide arm and top scan safety door sensors. Both operators initiated by 2no. radio controlled (transmitter/receiver) 4" push pads to either side of door. Push and go facility enabled on door set. Full signage.