Automatic
Entrance Systems
We offer a wide range of automatic entrance systems. These
include entrance products such as sliding, swinging, revolving
and bi-folding doors and low energy closers/operators to comply
with the Disability Discrimination Act 1995.
Our entrance systems for example are suitable for use in
schools, hospitals, residential homes, offices and retail
outlets.
We are able to incorporate access technology into the entrance/exit
device such as intercom, emergency, security and fire alarm
systems.
Sliding Doors
- Manufactured to comply with BS7036, Disability Discrimination
Act 1995 and the European directive EMC 89/336/EEC
- Commercial grade aluminium door/composite framework
- Safety signage and manifestation stripes/circles
- Single or Double Glazed (Safety glass)
- Low aluminium threshold
- Safety sensors/pocket where required to satisfy regulations
- Commissioned by experienced qualified engineers
- Colour to specification (Inclusive of header unit)
- Small and compact header section (Size of header section
means it can be installed in most locations)
Below Are Some Example Styles – More available on request
Note – Some styles may not be suited to location
 |
Internal
shuffle glazed for added security
Internal safety sensors to prevent slide door colliding
with traffic |
(Above) Style 1 – Single
slide door with low ramp threshold activated by external/internal
movement/proximity sensors.

(Above) Style 3 – Single
slide door with low ramp threshold activated by external/internal
movement/proximity sensors. Safety pocket – Internal

(Above) Single slide door with low ramp threshold
activated by external/internal movement/proximity sensors.
Internal safety sensors to slide area.
Swing Doors (Low Energy Door Operators)
Manufactured to comply with BS7036, Disability Discrimination
Act 1995 and the European directive EMC 89/336/EEC
Full range of low energy operators to suit most applications
Functions of Operators:
- Automatic
- Door stand open
- One/two way traffic
- Night lock
- Push and go – Manual opening by hand and closing
by spring
- Synchronisation of two operators – Two doors operating
simultaneously
- Safety sensors – Full safety optional extra
- Push button activation
- Adjustable time delay
- Adjustable – slow opening/closing speed
Operator Advantages:
- Low-Energy
- Automatic/manual
- Requires no structural changes
- Easy installation
 |

|
| Low Energy Unit –
Fitted to existing door
IPush Pad Entry located at 1mtre from ground level |
(Above) Interval view – Automated door via
low energy closer
 |
Internal door fitted with Intercom, Maglock and digital
access coded pad
(Linked to fire alarm system)
Wireless radio controlled – Reduces wiring and
simplifies fitting process
Key Switch – Auto, open, close, off, exit only
and entry only |
(Above) External powder coated commercial grade
aluminium composite frame with out swing door with integral
low threshold ramp. Door operated by 1no. low energy closer.
Above fanlight manufactured to suit existing archway. Door
glazed in 4mm clear toughened low ‘E’, 16mm cavity
and 4mm clear toughened.
 |
Barrier Rail – Attached 1no. press pad for external
application (Entry device) |
(Above) External powder coated commercial grade
aluminium composite frame with out swing door and integral
low threshold ramp with barrier rail. Door operated by 1no.
low energy closer. Door glazed in 6mm clear toughened low
‘E’, 12mm cavity and 6mm clear toughened.

(Above) The supply and fitting of 1no. low energy
door closer and mag-lock entrance/exit device to existing
master/slave powder coated aluminium door by AllGlass Systems
Ltd. door engineers.
(Above) 1no. aluminium hexagonal composite with
double door powered by 2no. low energy automated door closers.
Full top scan safety sensors and EZ+ microwave sensor for
early detection and safe passage of door users.
AGS 2004 Header Unit
AGS 3 Position Key Switch (Can be Wall or Frame Mounted)
Articulated Arm (Open Out)
2 Channel Receiver

Closed Position |

Part Open
|

Fully Open |
|
AGS 2009 Header Unit
Slide Arm (Open In)
2 Channel Receiver
Fuse Spur (By Others)

Example 1 |

Example 2
|
Magnetic Lock – Secure Access

Figure 1 – Front (Frame Mounted) |

Figure 2 – Rear (Frame
Mounted)
|

Figure 3 – Door Attachment |
|
Mag-Lock
- Fail Safe
- Fail Secure (Battery back Up)
Operated by:
- Emergency Door Release – Figure 4
- Press to Open 4” Push Pad (Hard Wired/Radio Controlled)
– Figure 5
- Stainless Steel Digital Key Code Pad – Figure 6
- Infrared Touch-less Switch – Figure 7
- Handset (Visual/Audio) with Push Button Release
- Remote Control
- Integrated with Fire Alarm System (Interfaced by Qualified
Systems Technician)

Figure 4 – Emergency Door
Release |

Figure 5 – Press To Open
4” Push Pad (Transmitter)
|

Figure 6 – Stainless Steel
Digital Key Code Entry System |

Figure 7 – Infrared Touch-less
Switch
|
Revolving Doors
- Manufactured to comply with BS7036, Disability Discrimination
Act 1995 and the European directive EMC 89/336/EEC
- Typical installation sites – Hospitals, Hotels,
Supermarkets, Department Stores, Airports and Office Buildings
- Automatic operation – Activated by motion detectors
- Safety features/sensors – Emergency stop if door
encounters an object, reduced speed and a focused on door
system that detects objects within a certain distance.
- Commissioned and installed by experienced qualified engineers
- Colour to specification (Inclusive of header unit)
- Directional control – Security (with optional card
access)
- Manufactured to satisfy the needs of the location/application
- Safety glass as standard
Bi-folding Doors
- Manufactured to comply with BS7036, Disability Discrimination
Act 1995 and the European directive EMC 89/336/EEC
- Suited to locations where space is at a premium.
- Concertina style
- Designed for use in corridors, hallways, small vestibules
or disabled entrances
- Accommodates two way traffic
- Commissioned and installed by experienced qualified engineers
- Colour to specification (Inclusive of header unit)
- Manufactured to satisfy the needs of the location/application
- Safety glass as standard
Conversion of Existing Internal Door
Set to Automated
(Above) 2no. low energy automated door operators
with slide arm and top scan safety door sensors. Both operators
initiated by 2no. radio controlled (transmitter/receiver)
4" push pads to either side of door. Push and go facility
enabled on door set. Full signage.
(Above) 2no. low energy automated door operators
with slide arm and top scan safety door sensors. Both operators
initiated by 2no. radio controlled (transmitter/receiver)
4" push pads to either side of door. Push and go facility
enabled on door set. Full signage.
|